MDT - Dual analog input/output, recessed, input voltage 0-10V/2-10V or current loop 0-20mA/4-20mA output voltage

Out-of-Stock
CHF152.90
Tax included
Stock status: Out of stock
Out of stock

The Analog In-/Output MDT is suitable for controlling devices with 0-10V inputs and for retrieving 0-20mA/0-10V measurement data. All channels are galvanically isolated from the KNX bus and can be configured independently of each other as input or output.

Out-of-Stock
Brand MDT SKU AIO-0210V.01

description

The Analog In-/Output MDT is suitable for controlling devices with 0-10V inputs and for retrieving 0-20mA/0-10V measurement data. All channels are galvanically isolated from the KNX bus and can be configured independently of each other as input or output.


The input voltage range is 0-10V or 2-10V, optional inputs can be used as a current loop with 0-20mA or 4-20mA. Each input can be set individually with the ETS. The min/max, threshold and traffic light functions are available, the conversation of the unit of measurement and the DPT can be configured.

function

  • Each channel can be configured independently (input/output).
  • The inputs/outputs are galvanically isolated from the bus.
  • The inputs/outputs are galvanically connected to each other.
  • The voltage for output operation is generated inside the actuator.
  • No external power supply is needed
  • Operation of input 0-10V/2-10V or 0-20mA/4-20mA (switchable)
  • Conversation of the unit of measure and the configurable DPT
  • Min/Max function, wire break detection
  • Threshold and traffic light function
  • 0-10V output functions:
  • Control by 1Byte, 2Byte float, or 1Bit objects
  • Day/night function to limit the control value
  • Emergency mode in case of failure of the given value
  • Recessed mounting in an installation box
  • Dimensions (L x H x D): 41mm x 41mm x 12mm
  • Fast app download (long frame support for ETS5)
  • Integrated bus coupling unit
  • 3-year warranty

Technical specifications

  • Number of channels 2
  • Input voltage 0-10V 2-10V
  • Internal resistance 130kΩ
  • Current loop range 0-20mA 4-20mA
  • Resistance 266Ω
  • Output voltage 0-10V
  • Output current max. 2mA
  • Load resistor min 5kΩ
  • KNX TP-256 interface specification
  • Application software available ETS 4/5
  • KNX bus connection terminal 0.8mm Ø, solid core
  • Knx bus power supply
  • Power consumption of the KNX typ bus. <0.3W
  • Operating temperature 0 bis + 40°C
  • IP Enclosure 20
  • UP dimensions (L x H x D) 41mm x 41mm x 12mm

Specifications

Type Accessories for Smarthome gateways Gateways/Antennas Module
Protocol IP KNX